Parameter | Value |
|---|---|
Suspended Solid measure | |
Principle of measure | Optical IR (870 nm) based on IR absorption |
Range of measure | SS: 0-50 g/L / Turbidity: 0-4000 FAU / Sludge blanket: 0-100% |
Resolution | SS: 0.01 g/L / Turbidity: 0.01 to 1 FAU / Sludge blanket: 0.01 to 0.1% |
Accuracy | SS: < 10% / Turbidity: +/- 5% (range 200-4000 FAU) / Sludge blanket: +/- 2% |
Response time | < 35 secondes |
Temperature measure | |
Principle of measure | NTC |
Working temperature | -5.00°C to +60.00°C |
Resolution | 0,01 °C |
Accuracy | +/- 0.5 °C |
Storage Temperature | -10°C to +60°C |
Degree of protection | IP 68 |
Signal Interface | Modbus RS-485 or SDI-12 |
Refreshment of the measure | Maximum < 1 seconde |
Power supply | 5 to 28 volts |
Consumption | Standby: 25 µA (5V) / Average RS485 (1 measure/seconde): 4.5 mA (5V) / Average SDI12 (1 measure/seconde): 4.5 mA (5V) / Current Pulse: 100 mA during 30 mS / Heating times: 100 mS |
Sensor | |
Weight | 750 g (sensor) |
Material | DELRIN, Nickel-plated brass, EPDM |
Pressure max. | 5 bars |
Cable / connexions | 9 armoured connectors, polyurethane jacket, bare-wires or waterproof Fisher connector |