Aqualabo

LowTuS

Parameter

Value

Measurements


Measurement principle

Diffusion IR at 90° - ISO 7027

Measuring Range

0-10; 0-100 NTU & Automatic Range

Resolution

0,0001 NTU for [0,0002 to 9,9999 NTU] / 0,001 NTU for [10,000 to 100,00 NTU]

Accuracy

Low range: +/-2% of reading or 0,03 NTU* / High range: +/-5% or 0,2 NTU* — *Highest value

Temperature

NTC

Temperature Accuracy

+/- 0.5°C

Type of detector

Si photodiode

Light sources

IR LED 850 nm

Measurement frequency min

0.75s (measure only), 6s (measure + cleaning)

Ingress Protection rating

IP65

Maximum pressure

3.5 bar

Water Flow

100 ml/min to 1500 ml/min

Operating temperature

0-40°C

Storage temperature

0-50°C

Weight

1800 – 2000g depending on the version

Equipment

Body: Polycarbonate, POM-C, PE, polyamide / Optical windows: Fused silica / Cable: Bare wire with polyurethane sheath / Seals: Nitrile / Wiper unit: Silicon, Stainless steel

Wetted materials

Measurement cell: POM-C, Fused silica, Nitrile / Wiper unit: Silicon, Stainless steel

Cable

9 shielded conductors in 3, 7 and 15m. Other lengths on request

Signal interface

Modbus RS-485 — 1: The sensor responds in Modbus including during Standby

Parameter

Measure only

Measure + Cleaning

Sensor Power Supply

6.5 - 26 VDC — 1: Minimum voltage subject to cable length-related losses; 2: 28.0V absolute maximum

6.5 - 26 VDC

Typical consumption at 5V / 6.5V

Automatic standby: less than 4.0 mA* (26 mW) / Maximum peak current: 400 mA (10 ms)


Maximum current during measurement

180 mA (1170 mW)

300 mA (1950 mW)

Average current during measurement

95 mA (617.5 mW)

190 mA (1235 mW)

Average current (1 measurement / 10s) *

12 mA (78 mW)

125 mA (812.5 mW)

Energy for 1 measurement

172 µWh

1715 µWh

Typical consumption at 12V

Automatic standby: less than 4.0 mA* (48 mWh) / Maximum peak current: 250 mA (10 ms)


Maximum current during measurement

150 mA (1800 mW)

150 mA (1800 mW)

Average current during measurement

60 mA (720 mW)

110 mA (1320 mW)

Average current (1 measurement / 10s) *

10 mA (120 mW)

65 mA (780 mW)

Energy for 1 measurement

200 µWh

1833 µWh

Typical consumption at 24V

Automatic standby: less than 4.0 mA* (96 mW) / Maximum peak current: 150 mA (10 ms)


Maximum current during measurement

80 mA (1920 mW)

100 mA (2400 mW)

Average current during measurement

50 mA (1200 mW)

80 mA (1920 mW)

Average current (1 measurement / 10s) *

10 mA (240 mW)

50 mA (1200 mW)

Energy for 1 measurement

333 µWh

2667 µWh

EMC compliance

NF EN 61326-1: 2021-06 / RS-485 Modbus RTU — 1: The sensor is qualified for standard use with a dedicated cable including power supply and communication lines specific to the sensor network; 2: When connected to a DC power supply network separated from the RS485 communication lines, additional shielding must be used on the system to protect the sensors from induced surges (above 30 meter cable length)


Warranty

2 years


Learn more from our blog